We are convinced that with joint endeavours, the small business between us will bring us mutual benefits. We could assure you products quality and competitive selling price for Pipe Insulation Requirements , Insulation Solutions , Foam Rubber , We sincerely hope to serve you and your business with a good start. If there is anything we can do for You, we shall be more than pleased to do so. Welcome to our factory for visit.
Big discounting Black Corlor Rubber Foam Insulation Sheet Roll - TUBE-1203-1 – Kingflex Detail:

Description

Kingflex thermal insulation pipe/tube uses NBR(nitrile-butadiene rubber) as main raw material for foaming and become a fully closed cell of flexible rubber insulation material , without any fiber material like HCHO and CFCs which are bad for ozonosphere. Suitable for thermal insulation of various pipes and equipment (-50℃-110℃).

● nominal wall thicknesses of 1/4”, 3/8″, 1/2″, 3/4″,1″, 1-1/4”, 1-1/2″ and 2” (6, 9, 13, 19, 25 , 32, 40 and 50mm)

● Standard Length with 6ft (1.83m) or 6.2ft(2m).

IMG_8973
IMG_8898

Technical Data Sheet

Kingflex Technical Data

Property

Unit

Value

Test Method

Temperature range

°C

(-50 – 110)

GB/T 17794-1999

Density range

Kg/m3

45-65Kg/m3

ASTM D1667

Water vapor permeability

Kg/(m.s.pa)

 ≤0.91×10 ﹣¹³

DIN 52 615                           BS 4370 Part 2 1973

μ

-

≥10000

 

Thermal Conductivity

W/(m.k)

≤0.030 (-20°C)

ASTM C 518

≤0.032 (0°C)

≤0.036 (40°C)

Fire Rating

-

Class 0 & Class 1

BS 476 Part 6 part 7

 Flame Spread and Smoke Developed Index

25/50

ASTM E 84

Oxygen Index

≥36

GB/T 2406,ISO4589

Water Absorption,%by Volume

%

20%

ASTM C 209

Dimension Stability

≤5

 ASTM C534

Fungi resistance

-

Good

ASTM 21

Ozone resistance

Good

GB/T 7762-1987

Resistance to U.V. and weather

Good

ASTM G23

Advantages

● Excellent performance. Kingflex insulation pipe is made of NBR and PVC.It doesn’t contain fibrous dust, benzaldehyde and chlorofluorocarbons. Moreover, it has low conductivity & heat conductivity, good moisture resistence, and fireproof.

● Widely used. The insulated pipe can be widely used in cooling unit and equipment of central air conditioning, freezing water pipe ,condensing water pipe,air ducts ,hot-water pipe and so on.

● Easily to be installed. The insulated pipe not only can be easily installed with the new pipeline,but also can be used in the existing pipeline.The only  thing you need to do is to cut it,then glue it.Moreover,it doesn’t have negtive influence of the performance of the insulated pipe.

● Delivery on time. The products are stock and the quantity of supplying is large.

● Personal service. We can offer the service according to the customers’ requests.

Certification

sdsadasdas (1)

Application

xsdg

Exhibition

jrtf


Product detail pictures:

Big discounting Black Corlor Rubber Foam Insulation Sheet Roll - TUBE-1203-1 – Kingflex detail pictures

Big discounting Black Corlor Rubber Foam Insulation Sheet Roll - TUBE-1203-1 – Kingflex detail pictures


Related Product Guide:

We normally think and practice corresponding on the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and also the living for Big discounting Black Corlor Rubber Foam Insulation Sheet Roll - TUBE-1203-1 – Kingflex , The product will supply to all over the world, such as: Riyadh, Czech, Slovenia, Our company regards "reasonable prices, high quality,efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits in future. Welcome to contact us.
  • Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Joa from Frankfurt - 2017.11.20 15:58
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Heather from Algeria - 2018.11.06 10:04