Kingflex Technical Data |
|||
Property |
Unit |
Value |
Test Method |
Temperature range |
°C |
(-50 – 110) |
GB/T 17794-1999 |
Density range |
Kg/m3 |
45-65Kg/m3 |
ASTM D1667 |
Water vapor permeability |
Kg/(m.s.pa) |
≤0.91×10 ﹣¹³ |
DIN 52 615 BS 4370 Part 2 1973 |
μ |
- |
≥10000 |
|
Thermal Conductivity |
W/(m.k) |
≤0.030 (-20°C) |
ASTM C 518 |
≤0.032 (0°C) |
|||
≤0.036 (40°C) |
|||
Fire Rating |
- |
Class 0 & Class 1 |
BS 476 Part 6 part 7 |
Flame Spread and Smoke Developed Index |
|
25/50 |
ASTM E 84 |
Oxygen Index |
|
≥36 |
GB/T 2406,ISO4589 |
Water Absorption,%by Volume |
% |
20% |
ASTM C 209 |
Dimension Stability |
|
≤5 |
ASTM C534 |
Fungi resistance |
- |
Good |
ASTM 21 |
Ozone resistance |
Good |
GB/T 7762-1987 |
|
Resistance to U.V. and weather |
Good |
ASTM G23 |
With nitrile rubber as the main raw material, it is foamed into a flexible rubber-plastic heat-insulating material with completely closed bubbles, which makes the product widely used in various public places, industrial plants, clean rooms and medical education institutions.
Kingflex insulation products have passed BS476,UL94,CE,AS1530,DIN, REACH and Rohs certificates. Quality is guaranteed.
Kingflex, a manufacturing and trading combo,produce and export rubber foam insulation products for more than 40 years since 1979. We are also North of Yangtze river–the first insulation material factory. Our factory occupies 130000 square meter. We have bright workshop and clean warehouse.